广州伟伯科技有限公司
您的位置:首页 > 产品中心 > Total Petroleum Hydrocarbons (TPH) in Water
产品搜索:

Total Petroleum Hydrocarbons (TPH) in Water

产品编号:3253631
规格:Proficiency Testing Material
包装规格:2 ML
产品类别:进口试剂
品牌:Supelco
优惠价:立即咨询
产品价格
产品编号包装单位单价(元)国内现货国外库存询价单
32536312 ML1240
产品性质
Quality Level【质量水平】
100
packaging【包装】
ampule of 2 × 2 mL
application(s)
environmental
format【格式】
matrix material
基本信息
General description【一般描述】
Total Petroleum Hydrocarbons (TPH) in Water proficiency testing material is produced in accordance with ISO/IEC 17043:2010. This sample is produced according to TNI requirements. However, please note, this sample may include non-TNI analytes as well. The PT portfolio allows our test components to offer significant performance data to monitor and prove competency to customers, accreditation bodies or both.

Supelco® is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. Most water PT samples are available as concentrates or ready-to-use volumes giving the end-user flexibility in selecting samples that will fit their exact needs. Our WP program is designed to meet the quality assurance requirements, thereby ensuring the analytical competence of your laboratory.
These samples are typically provided in duplicate for use in case of lab mishap, for QC purposes or to analyze multiple methods.

Type of PT Scheme: Water analysis - Water Pollution (WP)

Matrix: Water Pollution/Wastewater

Analyte/s: Values of analytes vary lot to lot.

All information regarding the use of Total Petroleum Hydrocarbons (TPH) in Water can be found in the reporting packet which will be available to download at PT Portal.
Application【应用】
Total Petroleum Hydrocarbons (TPH) material in Water is a PT standard, suitable for testing non-polar extractable material and total petroleum hydrocarbons in environmental samples.
This ampule contains a concentrate for preparation of a solution that can be analyzed for TPH in Water

Have any questions? Explore our FAQs.
For more information on this product, please contact our PT Service Team.
Features and Benefits【特点和优势】
We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.

Our proficiency testing (PT) program is a benchmark to:

  • provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process
  • provide a comparison of performance with that of other laboratories, nationally and internationally
  • test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems
  • provide an independent evaluation of laboratory performance
  • demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality

Preparation Note【制备说明】
Description

  • This concentrate sample is formulated for the determination of TPH in water by GC - FID/PID, IR or gravimetric methods.
  • TPH consists of a light petroleum hydrocarbon (>10 to <36).
  • This solvent has the proper boiling point and IR spectra as to not interfere with the methods.
  • Handle the concentrate in a properly ventilated hood.

Sample Preparation


  • Transfer exactly 1 mL of concentrate directly to the separatory funnel.
  • Add 1 L of reagent grade DI water to the separatory funnel.
  • Considere this as your sample for test.
  • Proceed with analysis.
  • TPH is reported in mg/L.
  • Assume sample volume is 1 L for calculation purposes.
Other Notes【其他说明】
Are you new to Supelco® Proficiency Testing? Be sure to register your account details in the PT Portal before placing your order.
This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at ptservice@milliporesigma.com.

When placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.
Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.

Proficiency testing samples are presented as single blind. No values for the samples are released until the testing period concludes.

Proficiency Testing Schedule (2021-2022)


Wastewater
WP21-2March 24 - May 7, 2021
WP21-4September 22 - November 5, 2021

WP22-2March 23 - May 6, 2022
WP22-4September 21 - November 4, 2022
Legal Information【法律信息】
Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany
产品说明
Storage and Stability【储存及稳定性】
Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.
安全信息
Storage Class Code【储存分类代码】
12 - Non Combustible Liquids
WGK
WGK 3
广州伟伯科技有限公司 版权所有 CopyRight ©2006-2024, All Rights Reserved
工信部备案号:粤ICP备08114744号   Page Run Time: 0.0095